HEART IMAGING SOFTWARE

Speak with our team

03 / LEFT ATRIAL APPENDAGE CLOSURE

Plan appendage closure from CT.

QuanLAAC uses cardiac CT to measure the left atrium and appendage, mark the opening and landing zone, and compare closure devices.

Request a QuanLAAC demo →

The device view shows geometric fit. It does not simulate device or tissue forces.

01Left atrium & appendageLeft Atrial Appendage Closure

Left atrium & appendage.

Review the left atrium and appendage, measure their volumes, and trace the appendage centreline.

QuanLAAC · left atrium and appendage segmentation for reader review
02Axis & morphologyLeft Atrial Appendage Closure

Confirm the appendage axis.

Review the centreline, appendage length, bends, depth, and suggested morphology. The confirmed axis guides the ostium and landing-zone views.

QuanLAAC · centreline, length, lobes, bend angle, and morphology
03Ostium definitionLeft Atrial Appendage Closure

Ostium definition.

Mark the opening using nearby structures as guides. Review its minimum and maximum width, perimeter, and area.

QuanLAAC · ostium and opening measurements on CT
04Family-specific landing zonesLeft Atrial Appendage Closure

Family-specific landing zones.

Measure the landing-zone width and usable depth for each supported device type.

QuanLAAC · device-specific landing zone, dimensions, and usable depth
05Contrast fillingLeft Atrial Appendage Closure

Review contrast filling.

Review low-density regions in the appendage and compare delayed-phase images when available. CT attenuation alone cannot distinguish thrombus from slow flow. Compare delayed-phase images when available and review the finding clinically.

QuanLAAC · contrast filling review; low attenuation may reflect slow flow or thrombus
06Sizing & compressionLeft Atrial Appendage Closure

Sizing & compression.

Compare device sizes, expected compression, and depth. Check shallow appendages and nearby lobes.

QuanLAAC · compare device fit, compression, and usable depth
07DeploySIMGeometric deployment simulation

Preview device deployment.

Animate the selected device in the measured appendage and review its shape, compression, wall gap, and contact. This is a geometric, kinematic simulation; it does not calculate device or tissue stress.

QuanLAAC DeploySIM · device position, compression, and geometric fit
08LAACAssistLeft Atrial Appendage Closure

LAACAssist.

Review the selected working view and planned device depth. Record the deployed diameter and complete checks for position, stability, compression, and seal.

QuanLAACAssist · working view, planned depth, deployed diameter, and release checks

THE WORKFLOW

How the workflow works.

  1. 01Phase & segmentation
  2. 02Appendage axis
  3. 03Ostium
  4. 04Landing zone & depth
  5. 05Device fit
  6. 06LAACAssist

Review the scan and measurements at each step.

REPORT CONTENTS

What the report can include.

  • Ostium & landing-zone measurements
  • Usable appendage depth
  • Device-size comparison
  • Compression and geometric gaps
  • Working-view projections

SPHYGMA / QUANLAAC

See this module in a demo.

Request a demo →